HEIDENHAIN 238-1022 - 1022 UVR DC-link voltage low: charging circuit activated

1022 UVR DC-link voltage low: charging circuit activated

The UVR charging circuit activated due to low DC-link voltage. The system is attempting to recover from a voltage sag condition.

Root Cause Summary

HEIDENHAIN alarm 238-1022 occurs when the DC-link voltage in the power supply unit drops below the minimum threshold, triggering the charging circuit to activate. This typically indicates power supply degradation, input voltage issues, or excessive load conditions on the TNC system.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check input voltage at power supply

    Measure AC input voltage at the power supply terminals. Verify voltage is within ±10% of rated voltage (typically 400V/480V 3-phase).

    Use proper PPE and lockout procedures when measuring high voltage

  2. 2

    Monitor voltage stability

    Use oscilloscope or power quality analyzer to check for voltage dips, spikes, or phase imbalances during machine operation.

    Check voltage during spindle acceleration and axis rapid moves when power demand peaks

  3. 3

    Verify facility power quality

    Check building electrical system for loose connections, overloaded circuits, or transformer issues affecting the CNC power supply.

    Coordinate with facility maintenance to check upstream electrical components

Service Recommendedmedium confidence

Call a technician if:

  • ·High voltage measurements required
  • ·Power supply component replacement needed
  • ·Persistent alarms after basic checks

Prevention

  • Install line reactors to reduce voltage transients
  • Implement regular power quality monitoring
  • Schedule preventive capacitor replacement every 7-10 years
  • Maintain proper cooling airflow around power supplies

Common Mistakes

  • Ignoring input power quality issues
  • Not checking regenerative resistor condition
  • Attempting repairs without proper high-voltage safety procedures
  • Replacing capacitors without addressing root cause of degradation