HEIDENHAIN 238-101F - 101F UVR wrong or no KDR connected
Alarm 238-101F indicates the UVR (undervoltage relay) module has detected incorrect inductance values from the KDR (commutating reactor) or cannot establish proper communication with it. This typically occurs due to faulty wiring connections, damaged commutating reactor components, or incorrect parameter settings in the TNC drive configuration.
HEIDENHAIN 238-101F - 101F UVR wrong or no KDR connected
101F UVR wrong or no KDR connected
The commutating reactor inductance is too low. It may be missing, incorrectly connected, or faulty.
Root Cause Summary
Alarm 238-101F indicates the UVR (undervoltage relay) module has detected incorrect inductance values from the KDR (commutating reactor) or cannot establish proper communication with it. This typically occurs due to faulty wiring connections, damaged commutating reactor components, or incorrect parameter settings in the TNC drive configuration.
Safety
Causes and Fixes
Power down and inspect KDR connections
Turn off main power and check all wiring connections between the commutating reactor (KDR) and the UVR module in the drive cabinet.
Ensure main power is OFF and wait 5 minutes for capacitor discharge before touching any connections.
Measure connection resistance
Use a multimeter to check continuity and resistance values on KDR wiring harness. Resistance should be within manufacturer specifications (typically 0.1-2 ohms).
Check for corrosion or oxidation on terminal connections which can cause high resistance readings.
Retighten and test connections
Clean and retighten all KDR connections, then power up system and monitor for alarm recurrence during drive enable sequence.
Apply dielectric grease to connections in humid environments to prevent future corrosion.
Call a technician if:
Prevention
Common Mistakes
Related Alarms
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.