HEIDENHAIN 238-101F - 101F UVR wrong or no KDR connected

101F UVR wrong or no KDR connected

The commutating reactor inductance is too low. It may be missing, incorrectly connected, or faulty.

Root Cause Summary

Alarm 238-101F indicates the UVR (undervoltage relay) module has detected incorrect inductance values from the KDR (commutating reactor) or cannot establish proper communication with it. This typically occurs due to faulty wiring connections, damaged commutating reactor components, or incorrect parameter settings in the TNC drive configuration.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Power down and inspect KDR connections

    Turn off main power and check all wiring connections between the commutating reactor (KDR) and the UVR module in the drive cabinet.

    Ensure main power is OFF and wait 5 minutes for capacitor discharge before touching any connections.

  2. 2

    Measure connection resistance

    Use a multimeter to check continuity and resistance values on KDR wiring harness. Resistance should be within manufacturer specifications (typically 0.1-2 ohms).

    Check for corrosion or oxidation on terminal connections which can cause high resistance readings.

  3. 3

    Retighten and test connections

    Clean and retighten all KDR connections, then power up system and monitor for alarm recurrence during drive enable sequence.

    Apply dielectric grease to connections in humid environments to prevent future corrosion.

DIY Feasiblehigh confidence

Call a technician if:

  • ·UVR module replacement required
  • ·Drive parameter corruption suspected
  • ·Multiple related drive alarms present

Prevention

  • Regular inspection of drive cabinet connections
  • Monitor drive cabinet temperature and humidity
  • Perform annual drive parameter backup
  • Keep spare UVR and KDR modules in inventory

Common Mistakes

  • Ignoring loose connection symptoms
  • Attempting to bypass KDR safety circuits
  • Using incorrect replacement part numbers
  • Modifying drive parameters without documentation