Heidenhain codes
HeidenhainPower SupplyIntermediate30-120 minutes

238-1006

HEIDENHAIN 238-1006 - 1006 UVR leakage current too high

1006 UVR leakage current too high

The UVR leakage current monitor has detected current exceeding permissible limits. There may be insulation problems in the system.

Root Cause Summary

The Heidenhain 238-1006 alarm, indicating high UVR leakage current, is typically caused by insulation breakdown in motor cables, power modules, or DC link connections. The most likely fix involves systematically checking and testing insulation resistance to ground using a megohmmeter and replacing or repairing damaged components. This issue often arises from environmental factors like moisture or wear over time.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Disconnect Motor Cables

    Power down the CNC machine and disconnect all motor cables from the power module and motor end. Ensure proper lockout/tagout procedures are followed to prevent accidental power-up.

    Label each cable before disconnection to avoid mix-ups during reassembly.

    Ensure the machine is fully de-energized before proceeding to avoid electrical shock.

  2. 2

    Test Insulation Resistance

    Using a megohmmeter set to 500V or 1000V (as per manufacturer specs), test the insulation resistance between each cable conductor and ground. Readings below 1 MΩ indicate insulation failure.

    Perform the test in a dry environment to avoid false readings due to moisture.

    Do not use a multimeter for this test; it will not provide accurate insulation resistance data.

  3. 3

    Replace or Repair Damaged Cables

    If low resistance is detected, inspect the cable for visible damage (cuts, abrasions, or burn marks). Replace the entire cable if damage is confirmed, or repair with proper insulation tape and heat-shrink tubing if minor and approved by the manufacturer.

    Use only OEM-specified cables to ensure compatibility and safety.

    Improper repairs can lead to recurring failures; ensure compliance with Heidenhain standards.

DIY Feasiblemedium confidence

Call a technician if:

  • ·If insulation resistance testing shows persistent low readings despite cable and connection checks
  • ·If power module replacement is required and internal diagnostics are beyond skill level

Prevention

  • Regularly inspect and clean electrical connections to prevent moisture and dust buildup.
  • Schedule annual insulation resistance testing as part of preventive maintenance.
  • Use cable conduits or protective sheathing in harsh environments to protect motor cables.
  • Monitor machine environment for humidity and temperature extremes that could degrade insulation.

Common Mistakes

  • Using a standard multimeter instead of a megohmmeter for insulation testing, leading to inaccurate results.
  • Ignoring minor cable damage or improper grounding, which can escalate into major faults over time.

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.