HEIDENHAIN 238-1002 - 1002 UVR DC-link voltage too high

1002 UVR DC-link voltage too high

The UVR power supply unit has detected DC-link voltage exceeding permissible limits. This is a critical power system fault.

Root Cause Summary

HEIDENHAIN alarm 238-1002 indicates the DC-link voltage in the power supply unit has exceeded safe operating limits. This typically occurs due to regenerative energy feedback during rapid deceleration, power supply component failure, or incorrect mains voltage configuration.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check axis acceleration parameters

    Access MOD function, select Machine Parameters, navigate to MP1020-MP1029 (axis acceleration values). Verify acceleration/deceleration rates are not excessive for the regenerative capacity.

    Typical deceleration should not exceed 80% of maximum rated values for continuous operation

  2. 2

    Inspect regenerative resistor circuit

    Check regenerative resistor for proper connection and resistance value. Measure resistance across regenerative resistor terminals - should match nameplate specification typically 47-68 ohms.

    Ensure power is OFF and capacitors discharged before measuring resistance

  3. 3

    Monitor DC-link voltage during operation

    Use TNC diagnostic screen (CTRL+DIAG) to monitor real-time DC-link voltage during programmed moves. Normal operation should be 540-580VDC, alarm triggers typically above 750VDC.

    Record voltage peaks during different feed rates to identify problematic motion profiles

Service Recommendedmedium confidence

Call a technician if:

  • ·DC-link capacitor replacement needed
  • ·Power supply module replacement required
  • ·Regenerative chopper circuit repair needed
  • ·Insulation breakdown confirmed

Prevention

  • Monitor DC-link voltage trends during routine maintenance
  • Implement gradual acceleration/deceleration profiles
  • Schedule regular power supply component inspection
  • Maintain proper environmental conditions to prevent moisture ingress

Common Mistakes

  • Ignoring regenerative resistor maintenance
  • Setting excessive axis acceleration parameters
  • Failing to verify mains voltage stability
  • Not properly discharging capacitors before testing