Heidenhain 231-A800 - A800 CC limit switch+

A800 CC limit switch +

Heidenhain TNC error 231-A800: A800 CC limit switch +. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

Alarm 231-A800 occurs when the machine axis exceeds the positive software limit defined in CfgAxParSafety/absLimitPos parameter. This safety alarm prevents mechanical damage by stopping axis motion when the programmed or manual traverse exceeds the configured positive boundary.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access machine parameters

    Press MOD key, select 'Machine parameters' from setup menu, navigate to CfgAxParSafety section for the affected axis.

    Always backup current parameters before making changes using the parameter export function.

  2. 2

    Check absLimitPos value

    Verify the absLimitPos parameter value against machine mechanical limits and required working envelope. Compare with machine drawings or previous parameter backup.

    Never set software limits beyond mechanical travel limits - this removes critical safety protection.

  3. 3

    Adjust parameter if necessary

    If parameter is incorrect, modify absLimitPos value ensuring it remains within safe mechanical limits. Cycle power to activate new parameter.

    Test new limits with slow manual movements before running programs.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder feedback errors persist
  • ·Hardware limit switches require replacement
  • ·Parameter changes don't resolve issue

Prevention

  • Regularly verify work offset values before program start
  • Train operators on software limit awareness
  • Implement soft limit warnings in machine parameters

Common Mistakes

  • Setting software limits too close to mechanical limits
  • Ignoring position display during manual operations
  • Not backing up parameters before modifications