Heidenhain codes
HeidenhainSystemIntermediate30-120 minutes

231-A830

HEIDENHAIN 231-A830 - A830 CC SRG rot. speed = 0

A830 CC SRG rot. speed = 0

This TNC 640 error indicates an internal control fault. The issue relates to The maximum permissible velocity is 0 (as per parameter).

Root Cause Summary

Alarm 231-A830 occurs when the TNC control detects that the spindle drive's maximum permissible velocity is set to 0% or invalid gear range parameters prevent spindle operation. This typically results from incorrect parameter configuration in the spindle drive settings or hardware safety circuit issues.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameters

    Press MOD key, select 'Machine Parameters' from the TNC menu, navigate to spindle parameters section.

    Machine parameter changes require appropriate access level and can affect machine safety.

  2. 2

    Check MP3110 Maximum Spindle Speed

    Locate MP3110 and verify the value is not 0. This parameter defines the maximum permissible spindle speed in RPM.

    Cross-reference with machine documentation for correct maximum spindle speed specification.

  3. 3

    Verify Related Speed Parameters

    Check MP3111 (minimum spindle speed) and ensure proper relationship between min/max values.

    Typical ratio should allow for reasonable speed range based on spindle motor specifications.

  4. 4

    Reset and Test

    After parameter correction, perform control reset (CTRL+ALT+DEL) and test spindle operation with M3 S500 command.

    Ensure spindle area is clear before testing rotation.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety circuit modifications required
  • ·Parameter backup/restore needed
  • ·Hardware component replacement necessary

Prevention

  • Regular parameter backup verification
  • Periodic keylock switch cleaning and lubrication
  • Safety circuit continuity testing during PM
  • Document all parameter changes with justification

Common Mistakes

  • Setting MP3110 to machine maximum instead of drive maximum
  • Forgetting to reset control after parameter changes
  • Ignoring gear range parameter relationships
  • Bypassing safety circuits during troubleshooting

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.