HEIDENHAIN 231-A8D0 - A8D0 SS1 still active—switch-on not allowed

A8D0 SS1 still active—switch-on not allowed

This TNC 640 error indicates an internal control fault. The issue relates to The safety software of the controller unit (SKERN-CC) has pr.

Root Cause Summary

Alarm 231-A8D0 occurs when the SKERN-CC safety software detects that an SS1 (Safe Stop 1) reaction is still active and has not completed its full sequence. The drive system cannot be re-enabled until the SS1 stop condition is properly cleared and acknowledged through the safety chain.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check emergency stop status

    Navigate to MOD > Safety > Safety Status and verify all emergency stop inputs show 'OK' status in the safety monitoring display.

    Never bypass safety circuits - always identify root cause first

  2. 2

    Reset emergency stop chain

    Physically reset all E-stop buttons by pulling/twisting to release, then check safety relay status in PLC diagnostics.

    Check for stuck E-stop buttons that appear reset but don't make proper contact

  3. 3

    Acknowledge safety system

    Press the safety acknowledgment button (typically F8 in safety menu) after confirming all safety devices are properly reset.

    Some systems require a specific sequence: Reset hardware first, then software acknowledgment

  4. 4

    Verify SS1 completion

    Monitor the safety status display to confirm SS1 state changes from 'ACTIVE' to 'READY' before attempting drive enable.

    SS1 completion requires both motion stop AND safety circuit continuity

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety relay replacement required
  • ·SKERN-CC hardware fault detected
  • ·Multiple safety devices failing simultaneously

Prevention

  • Regular safety switch testing and cleaning
  • Periodic safety relay contact inspection
  • Maintain proper door alignment and switch gaps
  • Keep safety circuit wiring secure and protected

Common Mistakes

  • Attempting to bypass safety circuits
  • Not waiting for complete SS1 sequence before reset
  • Ignoring intermittent safety switch issues
  • Resetting alarms without addressing root cause