231-A950

HEIDENHAIN 231-A950 - A950 Safely limited increment (SLI) exceeded

A950 Safely limited increment (SLI) exceeded

This TNC 640 error indicates an internal control fault. The issue relates to The maximum permissible path was exceeded in the Safely Limi.

Root Cause Summary

Alarm 231-A950 occurs when the Safely Limited Increment (SLI) function detects that an axis has exceeded its permitted incremental movement distance. This safety-critical alarm is triggered when the actual axis position deviates beyond the configured safe increment limit defined in machine parameter distLimitJog.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check current SLI increment setting

    Access MOD function and navigate to Settings → Machine → SLI Settings to verify the current increment value being used.

    The increment value is displayed in the SLI dialog box when activated

  2. 2

    Verify distLimitJog parameter

    In machine parameter menu, check MP7680.x distLimitJog for the affected axis to confirm the maximum allowed increment distance.

    Only qualified personnel should modify safety-related machine parameters

  3. 3

    Adjust increment value

    Reduce the SLI increment to a value below the distLimitJog limit, typically 50-80% of the maximum allowed value for safety margin.

    Use smaller increments near workpiece or fixture boundaries

DIY Feasiblemedium confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Servo drive tuning beyond basic parameters
  • ·Mechanical component replacement needed

Prevention

  • Regularly calibrate SLI increment values
  • Perform periodic backlash measurements
  • Monitor servo following errors during operation
  • Keep encoder systems clean and properly connected

Common Mistakes

  • Setting SLI increment too close to distLimitJog limit
  • Ignoring mechanical wear indicators
  • Modifying safety parameters without proper authorization
  • Not considering thermal expansion effects on positioning accuracy