231-AC00

HEIDENHAIN 231-AC00 - AC00 CC amplitude too high

AC00 CC amplitude too high

The encoder signal amplitude is above the permitted range, or the encoder's contamination signal is active. On exposed encoders this often means the scanning gap is too small; an excessive supply voltage can also be responsible.

Root Cause Summary

HEIDENHAIN alarm 231-AC00 indicates the encoder signal amplitude exceeds acceptable limits, typically caused by improper air gap adjustment, contamination on encoder surfaces, or electrical supply issues. This alarm protects the encoder system from damage due to excessive signal strength that can corrupt position feedback.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access encoder diagnostics

    Navigate to MOD function → Encoder Test → select affected axis encoder to view real-time amplitude values in EnDat diagnostics screen.

    Normal amplitude should be between 0.8-1.2V for most HEIDENHAIN encoders

  2. 2

    Measure air gap with feeler gauge

    Use 0.1mm feeler gauge to check air gap between scanning head and encoder scale. Gap should be 0.1-0.3mm depending on encoder type.

    Power down system before mechanical adjustments to prevent encoder damage

  3. 3

    Adjust scanning head position

    Loosen scanning head mounting screws and adjust position to achieve proper air gap. Retighten to specified torque and verify amplitude in encoder diagnostics.

    Make small adjustments - even 0.05mm changes significantly affect signal amplitude

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder scale physical damage detected
  • ·Multiple encoder alarms on different axes
  • ·Power supply voltage consistently out of specification

Prevention

  • Implement regular encoder cleaning schedule
  • Monitor encoder diagnostics during PM intervals
  • Maintain proper machine enclosure sealing
  • Use appropriate coolant deflectors near encoders

Common Mistakes

  • Adjusting air gap with power on
  • Using incorrect cleaning solvents
  • Ignoring gradual amplitude drift trends
  • Overtightening scanning head mounting screws

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.