HEIDENHAIN 231-A930 - A930 Safely limited speed (SLS) exceeded

A930 Safely limited speed (SLS) exceeded

This TNC 640 error indicates an internal control fault. The issue relates to SKERN-CC detected an impermissibly fast axis movement above.

Root Cause Summary

HEIDENHAIN alarm 231-A930 occurs when the SKERN-CC safety kernel detects axis movement exceeding the configured Safely Limited Speed (SLS) threshold during safety-critical conditions. This typically happens when safety doors are opened during machining or when SLS parameters are set too restrictively for the application.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check safety door status

    Navigate to MOD → Machine Parameters → Safety and verify door switch inputs in MP7500-MP7599 range. Check if door switches are properly wired and functioning.

    Never bypass safety door switches - this violates safety regulations

  2. 2

    Verify SLS speed settings

    Check MP7650-MP7659 (SLS speed limits) and ensure they are appropriate for your application. Compare against actual axis speeds when door was opened.

    Set SLS speeds 20-30% higher than typical door-open operations but low enough for safety

  3. 3

    Test door interlock sequence

    Perform controlled test by opening door during slow jog movement to verify SLS activation timing and speed monitoring.

    Use extremely slow speeds during testing

DIY Feasiblemedium confidence

Call a technician if:

  • ·SKERN-CC communication failures persist
  • ·Safety parameter changes don't resolve issue
  • ·Encoder hardware replacement needed

Prevention

  • Regular safety door switch maintenance
  • Periodic SLS parameter review
  • Monitor encoder signal quality trends
  • Document all safety parameter changes

Common Mistakes

  • Setting SLS speeds too high for safety
  • Ignoring intermittent door switch issues
  • Not coordinating parameter changes with safety assessment
  • Bypassing safety interlocks during troubleshooting