HEIDENHAIN 231-A880 - A880 1st violation of positive software limit range

A880 1st violation of positive software limit range

This TNC 640 error indicates an internal control fault. The issue relates to The drive moved into the positive limit-switch range for the.

Root Cause Summary

Alarm 231-A880 occurs when an axis physically moves beyond the positive software limit defined in machine parameter CfgAxParSafety/absLimitPos. This is the first violation detected, indicating the axis has exceeded its programmed safe travel range on the positive side.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check current work offset

    Press POS key, select 'Preset table' to view active G54-G59 offsets for the affected axis.

    Compare the work offset value plus your programmed coordinates against the machine limit

  2. 2

    Verify preset table entries

    Navigate to Setup > Preset table and check if the offset values are realistic for your part setup.

    Never enter arbitrary large values to 'fix' positioning issues

  3. 3

    Recalculate work offset

    Use manual probing or preset probe cycles (Cycle 1, 9, or 10) to establish correct work coordinate system.

    Always verify your setup with G0 moves in single block mode after changing presets

DIY Feasiblehigh confidence

Call a technician if:

  • ·Machine parameter changes required beyond operator level
  • ·Encoder or feedback system errors detected
  • ·Mechanical reference point problems identified

Prevention

  • Always verify work offsets after part setup changes
  • Use program simulation before running new programs
  • Regularly check tool length measurements
  • Maintain proper reference point procedures

Common Mistakes

  • Ignoring the alarm and just clearing it without investigation
  • Changing machine parameters without understanding the root cause
  • Not accounting for total coordinate system when programming
  • Assuming software limits are wrong instead of checking setup