axismd.ai
Heidenhain Controller
Safety · Intermediate · 30-120 minutes
HEIDENHAIN 231-A200 - A200 Brake test is not allowed
HEIDENHAIN alarm 231-A200 occurs when the system attempts to execute a brake test but prerequisite conditions are not met. This typically involves missing drive ready signals, open protective doors when required by safety parameters, or incorrect brake-to-drive assignments in the servo configuration.
HEIDENHAIN 231-A200 - A200 Brake test is not allowed
A200 Brake test is not allowed
This TNC 640 error relates to the motor brake system. The control has detected an issue with brake operation or testing.
Root Cause Summary
HEIDENHAIN alarm 231-A200 occurs when the system attempts to execute a brake test but prerequisite conditions are not met. This typically involves missing drive ready signals, open protective doors when required by safety parameters, or incorrect brake-to-drive assignments in the servo configuration.
Safety
Causes and Fixes
Check Drive Status in MOD 127
Access MOD 127 (Machine Parameters) and navigate to servo drive diagnostics. Verify RDY signal status for the affected axis.
Look for bit patterns in the drive status word - RDY is typically bit 0
Verify Inverter Enable Signal
Check parameter MP7300.x (Drive Enable) for the specific axis. Ensure the inverter enabling signal is active and not blocked by safety circuits.
Never bypass safety circuits - investigate why the enable signal is missing
Inspect Drive Hardware
Check physical connections to the servo drive, verify 24V supply to enable circuits, and examine drive LED status indicators for fault conditions.
Reset Drive System
Perform controlled drive reset via MOD 127 servo diagnostics menu. Monitor for proper RDY signal establishment during startup sequence.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.