Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

230-0008

HEIDENHAIN 230-0008 - No reaction from CC

No reaction from CC

The speed and current controllers shut down because of an error. As a result, the control reports no reaction from the CC.

Root Cause Summary

HEIDENHAIN alarm 230-0008 indicates the CC (Current Controller) module has stopped responding to communication from the TNC control. This typically occurs when the CC unit has shut down due to overheating, power supply issues, or internal hardware failure within the drive electronics.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check CC Module Temperature

    Access MOD function and navigate to System Info > Drive Status to check CC temperature readings. Normal operating temperature should be below 60°C.

    Use the TNC's built-in temperature monitoring in the drive diagnostics screen

  2. 2

    Inspect Cooling System

    Verify cabinet fans are operational and air filters are clean. Check for blocked ventilation around the CC module housing.

    Ensure main power is OFF before opening electrical cabinet

  3. 3

    Allow Cool-Down Period

    Power down system for 30 minutes minimum to allow CC module to cool. Monitor ambient temperature in electrical cabinet.

    Install additional cooling if ambient temperature consistently exceeds 40°C

  4. 4

    Reset and Monitor

    Power up system and monitor CC temperature continuously through MOD > System Info during operation to verify cooling effectiveness.

DIY Feasiblemedium confidence

Call a technician if:

  • ·CC module hardware replacement required
  • ·TNC communication interface hardware failure
  • ·Multiple CC modules affected simultaneously

Prevention

  • Maintain proper cabinet cooling and ventilation
  • Regular inspection of 24V power supply voltage and current
  • Keep communication cable connections clean and properly seated
  • Monitor CC module temperature trends during operation

Common Mistakes

  • Ignoring cooling system maintenance leading to overheating
  • Not checking 24V supply voltage under load conditions
  • Replacing CC module without verifying power supply integrity
  • Failing to transfer parameter settings to replacement CC module

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.