Parameter · Intermediate · 30-120 minutes
HEIDENHAIN 230-001B - For a parameter change the drive has to be deactivated (axis)
The root cause is attempting to modify protected drive or axis parameters while the servo drive is in an active/enabled state. Heidenhain TNC controls enforce strict parameter access control to prevent real-time changes that could cause instability, position loss, or motor damage. The drive must be in a safe, deactivated state before commissioning or configuration parameters can be altered.
HEIDENHAIN 230-001B - For a parameter change the drive has to be deactivated (axis)
For a parameter change the drive has to be deactivated (axis)
A parameter or parameter-set change required the drive to be deactivated first, but it was not. The new values were rejected by the control.
Root Cause Summary
The root cause is attempting to modify protected drive or axis parameters while the servo drive is in an active/enabled state. Heidenhain TNC controls enforce strict parameter access control to prevent real-time changes that could cause instability, position loss, or motor damage. The drive must be in a safe, deactivated state before commissioning or configuration parameters can be altered.
Safety
Causes and Fixes
Identify Parameter Being Modified
Check the alarm log detail to see which axis (%2) is affected. Note which machine parameter was being accessed - typically MP1xxx (axis-specific), MP3xxx (encoder), or MP4xxx (drive controller) parameters.
The alarm often occurs with parameters like encoder type (MP310x), current controller settings (MP43xx), or position monitoring windows (MP14xx).
Deactivate Main Voltage
Turn the main voltage switch on the control cabinet to OFF position. Wait for the voltage monitoring display on the TNC screen to show 0V. This fully deactivates all drive amplifiers.
Ensure machine is at a safe position before removing voltage. Note current position if resuming work after parameter change.
Access Parameter in MOD Mode
Press MOD key, enter password if required (typically 807667), navigate to the specific machine parameter. Make the required change while voltage is off. The parameter will now be accepted without alarm.
Changes to most drive-related MP parameters require a control restart to take effect - note this before proceeding.
Restore Power and Clear Alarm
Return main voltage switch to ON. Press CE (Clear Error) key to acknowledge alarm 230-001B. Check that all axes show ready status before attempting motion.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.