Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

230-0020

HEIDENHAIN 230-0020 - Failed to send internal message

Failed to send internal message

This TNC7/TNC 640 error indicates an issue with 230-0020. Error in the internal system communication.

Root Cause Summary

HEIDENHAIN alarm 230-0020 indicates a breakdown in internal system communication between TNC control modules, typically involving the NC kernel, PLC, or axis control processors. This communication failure prevents proper data exchange between critical system components, often triggered by hardware faults, software corruption, or system overload conditions.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check System Load Status

    Access MOD function → System Info → Performance Monitor to check CPU load and memory usage. Look for sustained loads above 85%.

    Use the diagnostic buffer (MOD → Diagnosis → System Messages) to identify which processes are generating excessive traffic.

  2. 2

    Clear Communication Buffers

    Perform controlled shutdown via MOD → Machine → Reset → Complete Reset. This clears all internal message buffers and reinitializes communication channels.

    Ensure all axes are at safe positions before performing complete reset.

  3. 3

    Verify System Parameters

    Check machine parameter MP7300 (System cycle time) and MP7310 (Communication timeout). Default values should be 4ms and 1000ms respectively.

    If values have been modified, restore to factory defaults and test system stability.

  4. 4

    Monitor Communication Recovery

    Run a simple positioning program while monitoring the diagnostic buffer for recurring 230-xxxx series alarms indicating persistent communication issues.

DIY Feasiblemedium confidence

Call a technician if:

  • ·Memory test reveals hardware failures
  • ·Hardware diagnostic tests fail
  • ·Multiple system resets don't resolve the issue
  • ·Physical damage to communication modules is suspected

Prevention

  • Maintain stable power supply with proper UPS protection
  • Keep control cabinet temperature within specified range
  • Perform regular system backups before making parameter changes
  • Monitor system performance regularly through diagnostic tools
  • Ensure proper EMI shielding around communication modules

Common Mistakes

  • Ignoring system load warnings before communication failures occur
  • Modifying communication timing parameters without understanding dependencies
  • Performing incomplete system resets that don't clear communication buffers
  • Overlooking environmental factors affecting communication hardware reliability

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.