Heidenhain Controller
Overheat/Thermal · Intermediate · 30-120 minutes
HEIDENHAIN 230-0026 - An HSCI participant has triggered the SS2/STOP2 stop reaction
The Heidenhain 230-0026 alarm typically indicates a safety stop reaction (SS2/STOP2) triggered by an HSCI participant due to issues like temperature problems or fan failures. The most common fix involves identifying the specific device reporting the error through bus diagnostics and addressing the underlying hardware issue, such as replacing a defective fan or cooling system component.
HEIDENHAIN 230-0026 - An HSCI participant has triggered the SS2/STOP2 stop reaction
An HSCI participant has triggered the SS2/STOP2 stop reaction
An HSCI node triggered an SS2/STOP2 safety reaction. This can stem from a failed self-test, an over-temperature device, or a broken fan.
Root Cause Summary
The Heidenhain 230-0026 alarm typically indicates a safety stop reaction (SS2/STOP2) triggered by an HSCI participant due to issues like temperature problems or fan failures. The most common fix involves identifying the specific device reporting the error through bus diagnostics and addressing the underlying hardware issue, such as replacing a defective fan or cooling system component.
Safety
Causes and Fixes
Access Bus Diagnostics
Use the TNCdiag tool or bus diagnostics feature on the control panel to identify the specific HSCI participant reporting a temperature issue. Look for bit REQ.SS2 in the local S status to pinpoint the device.
Save a screenshot or log of the diagnostics data for future reference or escalation.
Ensure the machine is powered down before accessing internal components if required.
Inspect Device Environment
Physically check the identified device for signs of overheating, such as hot surfaces or unusual odors. Verify that the ambient temperature around the machine is within the manufacturer’s specified range (typically 5-40°C).
Use an infrared thermometer for a quick, non-contact temperature check of the device.
Avoid direct contact with hot surfaces to prevent burns.
Check Cooling System
Inspect the cooling vents and heat sinks of the affected device for dust or blockages. Clean with compressed air if necessary, ensuring proper airflow. If the device has an active cooling system, confirm it is operational.
Schedule regular cleaning of cooling components to prevent recurring issues.
Disconnect power before cleaning to avoid electrical hazards.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.