Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

230-0044

HEIDENHAIN 230-0044 - Error in axis simulation

Error in axis simulation

This TNC7/TNC 640 error indicates an issue with 230-0044. Incorrect call of the controller unit during the simulation.

Root Cause Summary

This alarm indicates the TNC control's internal axis simulation engine has encountered data it cannot process correctly, typically due to parameter configuration errors or memory/software issues. The simulation module requires consistent axis definitions between real and simulated behavior, and any mismatch or corruption in these parameters triggers this protective alarm. Resolution requires verifying simulation-specific machine parameters and ensuring proper control software operation.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameters

    Press MOD key, enter password, select 'Machine Parameters' from the menu. Navigate to CfgAxisSim parameter group to review simulation settings.

    Document all current parameter values before making any changes. Incorrect parameter modifications can affect machine behavior.

  2. 2

    Verify Simulation Configuration Syntax

    Check CfgAxisSim entries for each axis (X, Y, Z, etc.) for proper syntax: valid numerical ranges, correct axis names matching CfgAxes definitions, and no special characters or formatting errors.

    Compare simulation parameters against a backup parameter file or factory defaults to identify discrepancies. Pay special attention to decimal separators and unit specifications.

  3. 3

    Reset to Default Simulation Parameters

    If corruption is suspected, restore CfgAxisSim parameters to default values from backup or factory settings. Document custom settings first for later reconfiguration.

    Resetting parameters will remove custom simulation behavior. Coordinate with machine tool builder if special simulation settings were implemented.

  4. 4

    Restart Control and Test

    Perform a complete control restart (power cycle or use MOD > System > Restart). After reboot, enter simulation mode (Test Run) and attempt to execute a simple axis movement program to verify alarm clearance.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hardware communication errors persist after cable inspection
  • ·Machine parameter corruption requiring factory defaults
  • ·Servo drive replacement needed

Prevention

  • Always exit simulation mode properly using MOD menu
  • Regularly backup machine parameters and NC programs
  • Verify program syntax before simulation runs

Common Mistakes

  • Modifying machine parameters without understanding dependencies
  • Forcing simulation mode reset without proper shutdown
  • Ignoring servo communication warnings before simulation

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.