Haas Alarm 1251 - SMTC Double Arm
Alarm 1251 SMTC Double Arm occurs when the Side Mount Tool Changer's dual-arm mechanism fails to complete proper sequencing during tool changes. The NGC control detects position feedback errors from the arm proximity switches or timing violations in the tool change macro sequence.
Haas Alarm 1251 - SMTC Double Arm
SMTC Double Arm
This alarm occurs on machines equipped with a Simultaneous Multi-Tool Changer (SMTC) system when the control detects both robot arms are attempting to move or occupy the same space at the same time, creating a collision risk. The MOCON board monitors position feedback from both arm assemblies and triggers this fault when the logic detects unsafe simultaneous motion or position conflict. Machine motion halts immediately to prevent damage to the SMTC mechanism.
Root Cause Summary
Alarm 1251 SMTC Double Arm occurs when the Side Mount Tool Changer's dual-arm mechanism fails to complete proper sequencing during tool changes. The NGC control detects position feedback errors from the arm proximity switches or timing violations in the tool change macro sequence.
Safety
Causes and Fixes
Check Arm Position Indicators
Navigate to CURRENT COMMANDS > ATC and observe arm position status lights. Both arms should show HOME when not in tool change cycle.
Use MDI mode and execute M19 (spindle orient) followed by M6 T0 to manually cycle arms and observe position feedback.
Test Proximity Switches
Access DIAGNOSTICS > INPUTS and monitor arm home switch inputs while manually moving arms (power off, E-stop active). Switches should toggle cleanly.
Ensure E-stop is active and spindle is locked before manual manipulation.
Inspect Sensor Mounting
Check proximity switch mounting brackets for looseness, proper gap (typically 1-2mm), and cable integrity. Clean metal sensing targets of debris.
Use a feeler gauge to verify consistent sensor gap across the entire sensing target travel.
Verify Wiring Continuity
Test continuity from proximity switches to the main control board connector, typically through the ATC junction box. Check for intermittent connections.
Power down machine and lock out electrical before continuity testing.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.