Fanuc Alarm PS010 - Invalid G-Code
Fanuc PS010 alarm occurs when the control encounters a G-code command that is either syntactically incorrect, not supported by the installed control series/options, or disabled through system parameters. This is commonly caused by posting programs for the wrong control configuration, using G-codes from newer control generations on older hardware, or missing software options.
Fanuc Alarm PS010 - Invalid G-Code
IMPROPER G-CODE
Fanuc alarm PS010: IMPROPER G-CODE. The part program or machine configuration has an error related to this alarm condition. Review the block indicated in the alarm screen and correct the command per the Fanuc programming manual.
Root Cause Summary
Fanuc PS010 alarm occurs when the control encounters a G-code command that is either syntactically incorrect, not supported by the installed control series/options, or disabled through system parameters. This is commonly caused by posting programs for the wrong control configuration, using G-codes from newer control generations on older hardware, or missing software options.
Safety
Causes and Fixes
At the alarm screen, note the exact G-code and line number (N-number) causing PS010. Press RESET and use EDIT mode to navigate to the flagged block.
Navigate to SYSTEM > PARAMETER and check parameter 3106#0-#7 and 3107#0-#7 (G-code system selection bits) to verify which G-codes are enabled. Cross-reference with your control's programming manual for the specific series.
Press SYSTEM > OPTION and verify installed software options. Look for options like High-Speed Machining (bit 2), AI Contour Control, 5-Axis Machining, or Smooth TCP depending on the G-code in question.
If the option is missing, either modify the post-processor to exclude unsupported G-codes or contact Fanuc/machine builder for option enablement. If the option is present, verify parameter 19500-19699 series for G-code specific enable/disable settings.
Enabling software options requires proper licensing and may need Fanuc service involvement