FANUC Controller
System · Advanced · 2-8 hours depending on parts availability
Fanuc Alarm 971 - NMI OCCURRED IN SLC
Alarm 971 NMI OCCURRED IN SLC indicates a Non-Maskable Interrupt has been detected in the Servo Logic Circuit board, pointing to a critical hardware fault. This is typically caused by memory corruption, electrical noise interference, or a failing SLC circuit board itself that requires immediate replacement.
Fanuc Alarm 971 - NMI OCCURRED IN SLC
SYSTEM ALARM 971
Fanuc alarm 971: SYSTEM ALARM 971. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Alarm 971 NMI OCCURRED IN SLC indicates a Non-Maskable Interrupt has been detected in the Servo Logic Circuit board, pointing to a critical hardware fault. This is typically caused by memory corruption, electrical noise interference, or a failing SLC circuit board itself that requires immediate replacement.
Causes and Fixes
Power down the system completely and perform a visual inspection of the SLC board for burnt components, bulging capacitors, or physical damage. Check for any unusual odors indicating component failure.
Disconnect all power and wait 5 minutes for capacitor discharge before handling boards.
Reseat the SLC board in its slot on the main CPU board or backplane. Clean the board edge connectors with contact cleaner and ensure proper seating with locking mechanisms engaged.
Power up and monitor alarm history via SYSTEM > ALARM > HISTORY. If alarm reoccurs immediately or within minutes, proceed to board replacement.
Replace the SLC board with a known good spare. After replacement, clear alarms and execute a parameter initialization sequence if required by the specific control series (consult service manual for SRAM/FROM reload procedures).
Ensure parameter and PMC program backups are current before board replacement. Battery voltage must be adequate during swap.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.