Fanuc Alarm 435 - Input AC Voltage Low

CNV AC Low Voltage

Fanuc alarm 435: CNV AC Low Voltage. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.

Root Cause Summary

Fanuc Alarm 435 indicates the DC link voltage in the servo amplifier has fallen below the minimum operational threshold, typically below 280VDC for 200V class or 540VDC for 400V class systems. This alarm protects the servo amplifier from operating outside safe voltage ranges and is triggered by input power issues, rectifier circuit failures, DC bus capacitor degradation, or regenerative discharge resistor problems.

Safety

  • Verify power is stable before running

Causes and Fixes

  1. 1

    Check DC link voltage at DIAGNOSIS > SERVO > DC LINK screen. Verify L-N voltage readings for all three phases (R, S, T). Normal DC link should read approximately 1.35x line-to-line AC voltage (280-310VDC for 200V class, 540-580VDC for 400V class).

  2. 2

    Measure incoming AC voltage at power supply module input terminals L1, L2, L3 with voltmeter. Verify balanced three-phase voltage within 2% tolerance. Check for loose connections, damaged contactors, or blown fuses in distribution panel.

    Use appropriate PPE and lockout/tagout procedures when measuring high voltage AC power

  3. 3

    Monitor AC voltage under dynamic load conditions during rapid traverse and acceleration. Voltage drop exceeding 10% indicates inadequate supply capacity, undersized wiring, or high impedance connections. Check branch circuit breaker rating matches amplifier requirements.

  4. 4

    Inspect PSM (Power Supply Module) LED indicators. Steady red or flashing LED patterns indicate input power faults. Check alarm history at DIAGNOSIS > ALARM HISTORY for related alarms (400, 401, 414) indicating power supply issues.

Service Recommendedmedium confidence

Call a technician if:

  • ·DC link capacitor replacement required
  • ·Rectifier bridge failure confirmed
  • ·Multiple related servo alarms present
  • ·High voltage electrical work needed

Prevention

  • Install line reactors to reduce voltage transients
  • Maintain proper cooling airflow through servo drives
  • Replace DC link capacitors every 5-7 years preventively
  • Monitor AC input power quality regularly

Common Mistakes

  • Not waiting for capacitor discharge before testing
  • Replacing individual capacitors instead of complete bank
  • Ignoring cooling system maintenance
  • Not checking AC input power quality first

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.