Fanuc Alarm 437 - Servo Parameter Invalid
Fanuc Alarm 437 indicates the Power Supply Module (PSM) has detected overcurrent in its input circuit, triggering protective shutdown. This is typically caused by shorted input wiring from the main power supply, degraded DC link capacitors in the PSM allowing excessive inrush current, or internal PSM component failure in the converter section.
Fanuc Alarm 437 - Servo Parameter Invalid
Parameter Invalid
Fanuc alarm 437: Parameter Invalid. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc Alarm 437 indicates the Power Supply Module (PSM) has detected overcurrent in its input circuit, triggering protective shutdown. This is typically caused by shorted input wiring from the main power supply, degraded DC link capacitors in the PSM allowing excessive inrush current, or internal PSM component failure in the converter section.
Safety
Causes and Fixes
Power down the system completely and lock out main breaker. Visually inspect all three-phase input wiring (R, S, T terminals) on the PSM for physical damage, pinched insulation, burn marks, or contamination.
Ensure proper LOTO procedures - residual high voltage remains in DC link capacitors for several minutes after shutdown
Using a megohm meter (500V setting), perform insulation resistance tests between each R/S/T input conductor and ground with wires disconnected from PSM. Minimum acceptable reading is 10 megohms; anything below 1 megohm indicates insulation failure.
Check continuity between R-S, S-T, and T-R phases with wires disconnected. Any reading below infinite resistance indicates a phase-to-phase short requiring immediate cable replacement.
Inspect PSM input terminal block for carbon tracking, loose connections causing arcing, or foreign debris bridging terminals. Clean with electrical contact cleaner and verify torque to specification (typically 1.5-2.0 N·m for αi series PSMs).
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.