FANUC codes
FANUCSystemAdvanced2-8 hours depending on parts availability

973

Fanuc Alarm 973 - NON MASK INTERRUPT

FANUC ALARM 973

A non-maskable interrupt has been generated. Typically indicates a hardware fault on the CNC main board or a connected module.

Root Cause Summary

Alarm 973 NON MASK INTERRUPT indicates a critical hardware-level fault that cannot be ignored by the CPU. This is typically caused by a defective main PCB (CPU board), memory corruption, faulty I/O module, or electrical noise/grounding issues affecting the control system. This alarm requires immediate attention as it represents a hardware failure that can cause system instability.

Causes and Fixes

  1. 1

    Power OFF the machine completely. Wait 30 seconds, then power ON and observe if alarm reoccurs immediately or intermittently. Document the alarm frequency pattern.

  2. 2

    Access SYSTEM > MAINTENANCE > ALARM HISTORY screen and record the exact time stamps and any related alarms (especially 9XX series system alarms) that occurred before or after the 973 alarm.

  3. 3

    Check diagnostic data at SYSTEM > DIAGNOSIS > check diagnostic numbers #7000-#7099 (system diagnostics) for any hardware fault indicators. Record any non-zero values.

  4. 4

    If alarm persists after power cycle, replace the main CPU board (MAIN PCB). Backup all parameters and programs via CF card or network before replacement. After installation, reload parameters and ladder, then verify operation.

    Ensure proper ESD precautions when handling control boards. Have replacement board configuration data ready.

Service Recommendedlow confidence

Call a technician if:

  • ·Memory test failures
  • ·Multiple I/O modules showing faults
  • ·CPU diagnostic test failures
  • ·Voltage readings outside tolerance

Prevention

  • Regular backup battery replacement every 2 years
  • Monthly temperature monitoring
  • Annual I/O module reseating
  • Quarterly power supply voltage verification

Common Mistakes

  • Assuming software issue when hardware diagnostics clearly indicate main board fault
  • Not checking backup battery voltage first
  • Replacing I/O modules without testing main board memory
  • Ignoring temperature warnings that precede NMI alarms

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.