Fanuc Alarm 740 - RIGID TAP ALARM: EXCESS ERROR
Fanuc alarm 740 occurs when the spindle position error during rigid tapping exceeds the allowable deviation threshold set in parameter 5200. This indicates the spindle cannot maintain synchronization with the Z-axis feed axis, commonly caused by encoder feedback issues, improper rigid tap parameters, mechanical binding, or insufficient spindle servo gain.
Fanuc Alarm 740 - RIGID TAP ALARM: EXCESS ERROR
SPINDLE ALARM 740
During rigid tapping, the spindle position deviation value is larger than the set value. Check spindle encoder, tapping parameters, and mechanical spindle-to-encoder connection.
Root Cause Summary
Fanuc alarm 740 occurs when the spindle position error during rigid tapping exceeds the allowable deviation threshold set in parameter 5200. This indicates the spindle cannot maintain synchronization with the Z-axis feed axis, commonly caused by encoder feedback issues, improper rigid tap parameters, mechanical binding, or insufficient spindle servo gain.
Causes and Fixes
Navigate to SYSTEM > DIAGNOSIS > [SPINDLE] and monitor diagnostics #0053 (spindle serial encoder alarm) and #0401-0404 (encoder pulse count). During manual spindle rotation, verify counts increment smoothly without jumps or freezing.
Check encoder cable connections at spindle motor and amplifier. Inspect for contamination, bent pins, or cable damage. For serial encoders, verify battery voltage at encoder (typical 3.0-3.6VDC) using diagnostic #0307 or multimeter at encoder connector.
Disconnect AC input power before inspecting amplifier connections to prevent electric shock
Monitor spindle amplifier LED codes during rigid tap cycle. Alpha-series amplifiers: steady green indicates normal, red blink codes indicate encoder errors (consult amplifier manual for specific patterns). Check for alarm history in SYSTEM > ALARM > [HISTORY] for related encoder alarms (SPI-xxx series).
Perform encoder one-rotation signal check: Navigate to SYSTEM > PMC > [SIGNAL] and monitor spindle one-rotation signal (typically G0073.1 or X address per ladder). Manually rotate spindle and verify single pulse per revolution. If absent or multiple pulses occur, replace spindle encoder.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.