Fanuc Alarm 742 - RIGID TAP ALARM: LSI OVERFLOW
Fanuc Alarm 742 RIGID TAP ALARM: LSI OVERFLOW occurs when the spindle position error counter in the spindle amplifier LSI exceeds its limit during rigid tapping (G84/G74). This indicates synchronization loss between spindle encoder feedback and commanded position, typically due to encoder issues, incorrect rigid tap parameters, or spindle drive problems.
Fanuc Alarm 742 - RIGID TAP ALARM: LSI OVERFLOW
SPINDLE ALARM 742
During rigid tapping, the spindle LSI error counter has overflowed. Check spindle encoder and rigid tapping parameters.
Root Cause Summary
Fanuc Alarm 742 RIGID TAP ALARM: LSI OVERFLOW occurs when the spindle position error counter in the spindle amplifier LSI exceeds its limit during rigid tapping (G84/G74). This indicates synchronization loss between spindle encoder feedback and commanded position, typically due to encoder issues, incorrect rigid tap parameters, or spindle drive problems.
Causes and Fixes
Check spindle encoder signals on DIAGNOSIS screen > SPINDLE > SP-FB (spindle feedback). Verify encoder position counts are stable and incrementing smoothly during manual spindle rotation. Check parameters 4020-4023 (serial spindle) or 4001-4008 (analog spindle) for encoder type settings.
Inspect spindle encoder cable connections at both encoder and amplifier. Check connector pins for damage, corrosion, or bent contacts. Verify cable routing away from power lines and proper shielding/grounding.
Power off CNC and amplifier before inspecting connections to prevent electric shock
Check spindle amplifier LEDs. READY should be solid green, ALM should be off. If encoder fault LED is illuminated, replace encoder cable first, then encoder if problem persists. Check alarm history (ALARM > HISTORY) for related spindle alarms (400-series).
Monitor DIAGNOSIS > SPINDLE > POSITION ERROR during manual rigid tap test at low RPM (100-200 RPM). Position error should remain within ±10 pulses. If error continuously grows or spikes, encoder or amplifier LSI is defective.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.