Fanuc Alarm 403 - SERVO ALARM: n-TH AXIS HARDWARE ERROR
Alarm 403 indicates a hardware-level fault detected within the servo amplifier circuit for the specified axis. This is typically caused by internal amplifier component failure, power supply issues to the amplifier, or feedback device communication errors that the amplifier cannot resolve. The alarm is generated when the amplifier's self-diagnostic detects a critical hardware malfunction.
Fanuc Alarm 403 - SERVO ALARM: n-TH AXIS HARDWARE ERROR
SERVO ALARM: n-TH AXIS HARDWARE ERROR
Hardware failure detected in the servo amplifier for the n-th axis. Check the servo amplifier LED display and diagnostic data.
Root Cause Summary
Alarm 403 indicates a hardware-level fault detected within the servo amplifier circuit for the specified axis. This is typically caused by internal amplifier component failure, power supply issues to the amplifier, or feedback device communication errors that the amplifier cannot resolve. The alarm is generated when the amplifier's self-diagnostic detects a critical hardware malfunction.
Causes and Fixes
Power down the CNC and check the servo amplifier LED display on the faulted axis. Record the LED pattern (typically 7-segment display showing alphanumeric codes). Refer to the amplifier hardware manual for LED code interpretation (common codes: 9, A, 25, 40 indicate hardware faults).
Ensure LOTO procedures before opening cabinet doors or inspecting amplifier modules.
Access DIAGNOSIS screen > SERVO > Check diagnostics #300-#399 series for detailed servo alarm information. Record diagnostic #397 (servo alarm detail) and #400-#407 (amplifier status) for the faulted axis.
Inspect the amplifier module for visible damage: burnt components, capacitor bulging, or discoloration. Check all connector cables between amplifier and motor (power and feedback cables) for damage or loose connections.
If amplifier shows hardware fault LED code and no external issues found, replace the servo amplifier module. After replacement, perform axis reference point return and verify operation. Check parameter 1815#0 (absolute position establishment) if using absolute encoders.
Replacing amplifier on absolute encoder systems requires position re-establishment procedure per Fanuc manual.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.