Fanuc Alarm 260 - Bar Feeder Error

Bar Feeder Alarm

Fanuc alarm 260: Bar Feeder Alarm. A peripheral machine system has reported a fault. This typically involves a machine-builder PMC alarm for a hydraulic, coolant, or auxiliary system.

Root Cause Summary

Fanuc Alarm 260 - Bar Feeder Error typically occurs due to issues with material flow or sensor detection in the bar feeder system. The most common cause is a material jam, often resolved by clearing obstructions and verifying alignment. Other frequent issues include feed motor errors or sensor malfunctions, which require systematic troubleshooting to identify and fix.

Safety

  • Material feed stopped

Causes and Fixes

  1. 1

    Power Down and Lockout

    Turn off the CNC machine and bar feeder, and apply lockout/tagout procedures to prevent accidental startup during inspection.

    Always double-check that power is fully disconnected using a multimeter if possible.

    Risk of injury if machine is not properly powered down.

  2. 2

    Inspect Feeder Path

    Visually inspect the bar feeder channel for obstructions, bent bars, or debris. Remove any visible blockages using appropriate tools like pliers or a brush.

    Use a flashlight to check hard-to-see areas of the feeder path for small debris.

    Wear gloves to avoid cuts from sharp metal edges.

  3. 3

    Test Manual Feed

    After clearing the jam, manually cycle the bar feeder (if possible) to ensure smooth movement. If resistance persists, check for misalignment in the feeder guides or collet.

    Mark the position of guide adjustments before tweaking to easily revert if needed.

    Do not force the feed if resistance is high; this could damage components.

DIY Feasiblehigh confidence

Call a technician if:

  • ·If motor or drive errors persist after basic checks and no electrical fault is found.
  • ·If sensor replacement or mechanical repairs do not resolve the issue and advanced diagnostics are needed.

Prevention

  • Regularly clean the bar feeder path to prevent debris buildup and jams.
  • Perform routine maintenance on sensors and motors as per the manufacturer's schedule.
  • Train operators on proper bar stock loading techniques and size specifications.
  • Always follow proper lockout/tagout procedures before any maintenance or inspection work.

Common Mistakes

  • Ignoring small jams or debris, leading to larger blockages or damage over time.
  • Bypassing sensor checks or alarms, which can mask underlying issues and cause further faults.

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.