Fanuc 265 - Retrace function not ready
Alarm 265 occurs when attempting to execute a retrace (restart) function but the control is not in the proper state to perform this operation. This typically happens when retrace conditions are not met, such as missing search data, incorrect machine state, or when the program has not been interrupted properly to allow restart functionality.
Fanuc 265 - Retrace function not ready
RETRACE FUNCTION NOT READY
Fanuc PS program alarm 265: RETRACE FUNCTION NOT READY. This alarm is triggered by an illegal or incorrectly formatted command in the part program, or a programming condition that the Fanuc control cannot execute.
Root Cause Summary
Alarm 265 occurs when attempting to execute a retrace (restart) function but the control is not in the proper state to perform this operation. This typically happens when retrace conditions are not met, such as missing search data, incorrect machine state, or when the program has not been interrupted properly to allow restart functionality.
Safety
Causes and Fixes
Check if the machine was powered off or reset after the program interruption - retrace data is lost on power cycle.
Verify that parameter 3407#0 (restart enable) is set to 1 to enable the retrace function.
Ensure the program was interrupted properly (FEED HOLD) rather than by RESET, which clears restart data.
If restart is required, return to program start, re-home the machine, and restart the program from the beginning or use block search with proper setup.
Ensure workpiece position matches program start conditions before restarting