Fanuc Alarm 055 - MISSING MOVE VALUE IN CHF/CNR
Fanuc Alarm 055 indicates the tailstock is not properly positioned or the system cannot verify its position before executing a machining operation. This alarm occurs when the PMC ladder logic detects a mismatch between the commanded tailstock position and the actual position feedback from limit switches or proximity sensors, or when position confirmation signals fail to activate within the programmed time window.
Fanuc Alarm 055 - MISSING MOVE VALUE IN CHF/CNR
MISSING MOVE VALUE IN CHF/CNR
Fanuc PS055: A chamfering (CHF) or corner rounding (CNR) command was programmed but no move value (axis address) was specified in the command block. A distance or radius value is required.
Root Cause Summary
Fanuc Alarm 055 indicates the tailstock is not properly positioned or the system cannot verify its position before executing a machining operation. This alarm occurs when the PMC ladder logic detects a mismatch between the commanded tailstock position and the actual position feedback from limit switches or proximity sensors, or when position confirmation signals fail to activate within the programmed time window.
Safety
Causes and Fixes
Navigate to PMC DIAGNOSIS screen (SYSTEM > PMC > PMCDGN) and identify the tailstock position input signals (typically G addresses like G0.0-G0.7 or G1.0-G1.7). Verify which signals should be ON for forward/retract positions.
Manually move tailstock to forward position using MPG or manual mode. Observe the corresponding input signal on PMC DIAGNOSIS screen. Signal should change from OFF to ON. Repeat for retract position.
If signal does not change, physically inspect limit switches or proximity sensors at tailstock assembly. Check for proper target positioning (1-2mm gap for proximity sensors), contamination (chips, coolant), damaged wiring, and secure connector seating at sensor and I/O terminal block.
Ensure machine is in emergency stop before inspecting mechanical components.
Using multimeter, measure continuity at the limit switch terminals or proximity sensor output (typically 24VDC NPN/PNP). Replace faulty sensors and re-verify signal response on PMC DIAGNOSIS screen.
Disconnect power to I/O circuits before performing continuity tests to prevent damage to PMC input modules.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.