Siemens SINUMERIK codes
Siemens SINUMERIKProbingIntermediate30-60 minutes

61312

Siemens 840D 61312 - Channel Block: Check measuring cycle number

Channel Block: Check measuring cycle number

The alarm can be triggered by the following measuring cycles: all measuring cycles. Remedy: Measuring cycle called is impermissible.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • Measuring cycle number does not exist in the active measuring cycle library or macro set
  • Incorrect measuring cycle syntax or parameter format in NC program
  • Measuring cycle not loaded or compiled in machine parameter configuration
  • Active tool offset or workpiece offset prevents execution of the specified measuring cycle
  • Measuring cycle called with missing or invalid required parameters

Troubleshooting Steps

  1. 1Verify the measuring cycle number exists in the machine's measuring cycle library by checking the active macro directory and _CYCLE.DEF file
  2. 2Review the NC block syntax where the alarm occurred - confirm cycle call syntax matches documentation (e.g., CYCLE822, CYCLE833) and all required parameters are specified
  3. 3Check machine parameters related to measuring cycle configuration - verify measuring cycles are enabled and properly linked in the control system
  4. 4Test the measuring cycle in manual mode using MDI to isolate whether the issue is program-specific or system-wide
  5. 5Load a known working measuring cycle program to confirm the measuring cycle feature operates correctly before re-running the original program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.