axismd.ai
Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 20-40 minutes
Siemens 840D 61320 - Channel Block: Check tool number
With active tool management, parameter _TNUM=0 and parameter _TNAME is not set or the specified tool name of tool management is unknown. The alarm can be triggered by the following measuring cycles: all measuring cycles. Remedy: Check parameter _TNUM, _TNAME.
Siemens 840D 61320 - Channel Block: Check tool number
Channel Block: Check tool number
With active tool management, parameter _TNUM=0 and parameter _TNAME is not set or the specified tool name of tool management is unknown. The alarm can be triggered by the following measuring cycles: all measuring cycles. Remedy: Check parameter _TNUM, _TNAME.
Safety
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.