Siemens 840D 61324 - Channel Block: Check 6th number of _KNUM
The specified position of _KNUM includes invalid values. Also check _MVAR. Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998, CYCLE114. Remedy: Check parameter _KNUM, _MVAR.
Siemens 840D 61324 - Channel Block: Check 6th number of _KNUM
Channel Block: Check 6th number of _KNUM
The specified position of _KNUM includes invalid values. Also check _MVAR. Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998, CYCLE114. Remedy: Check parameter _KNUM, _MVAR.
Safety
Refer to Siemens documentation
Ensure qualified technician performs repairs
Common Causes
Invalid or corrupted values in the 6th position of _KNUM parameter
Incompatible _MVAR parameter settings that conflict with _KNUM configuration
Incorrect tool offset or tool compensation table entries referenced by _KNUM
Memory corruption or failed parameter backup/restore operation
Mismatched parameter values between active cycles and stored _KNUM configuration
Troubleshooting Steps
1Access the alarm log and note the specific channel and block number where the alarm occurred; cross-reference with the active cycle program
2Retrieve and verify all values in _KNUM parameter, paying special attention to the 6th position entry; compare against valid parameter range documentation
3Inspect _MVAR parameter settings for conflicts or invalid entries that may interact with the flagged _KNUM position
4Clear the alarm, perform a parameter backup, then re-enter or restore _KNUM and _MVAR from a known good backup if available
5Re-run the triggering cycle (CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998, or CYCLE114) to confirm the alarm does not recur
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
Get machine-aware diagnosis
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.