Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisBasic10-20 minutes

61216

Siemens 61216 - Feed/tooth only possible with cutting tools

Feed/tooth only possible with cutting tools

Feed per tooth is only possible with milling tools Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • Feed per tooth is only possible with milling tools

Troubleshooting Steps

  1. 1As alternative, set a different feed type.
  2. 2Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.