Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate20-45 minutes

61223

Siemens 61223 - Block : Approach path too small

Block: Approach path too small

The approach path must not be less than zero Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The approach path must not be less than zero

Troubleshooting Steps

  1. 1Enter a greater value for the approach path.
  2. 2Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.