Siemens SINUMERIK codes
Siemens SINUMERIKSystemIntermediate30-120 minutes

4062

Siemens 840D 4062 - Backup data loaded

Backup data loaded

Siemens SINUMERIK 840D system notice 4062: Backup data loaded. This is a system-level notification regarding machine data or configuration. Note the message details and take the indicated action.

Root Cause Summary

Alarm 4062 is an informational message indicating that user data (machine parameters, tool offsets, zero offsets) previously stored in flash memory has been successfully loaded into SRAM during system startup or after a backup recovery event. This occurs when the NCK detects valid backup data in non-volatile storage and initiates the restoration sequence to working memory.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Verify backup enable status: Navigate to Diagnostics > Parameters > MD 18000 'Backup enable' and confirm it is set to 1 (enabled). Check MD 18010 'Backup mode' to confirm automatic restore is configured.

  2. 2

    Monitor the system startup log via Diagnostics > System > Startup Messages to confirm backup restoration completed without errors. The alarm 4062 should appear once during initial NCK initialization.

  3. 3

    Verify SRAM data integrity by checking active tool offsets (TOOL.T menu) and work offsets (WO.G menu) match expected values. If data appears corrupted, initiate a full backup restore from HMI: Service > Backup & Restore > Restore from Backup.

    Do not interrupt restore process once initiated

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.