Parameter · Intermediate · 30-120 minutes
Siemens 4060 - Standard machine data loaded ( , , , )
ALARM 4060 indicates that standard machine data (MD) have been reloaded into the NCK memory, typically due to loss of MD buffer backup power, a deliberate cold start, or MD initialization request via MD 11200. This is an informational alarm that documents a system state change rather than a fault condition.
Siemens 4060 - Standard machine data loaded ( , , , )
Standard machine data loaded (,,)
The standard MD were loaded because - a cold start was requested or - the MD buffer voltage failed or - an initialization was requested for loading the standard machine data (MD11200 $MN_INIT_MD) Control reaction: Alarm display.
Root Cause Summary
ALARM 4060 indicates that standard machine data (MD) have been reloaded into the NCK memory, typically due to loss of MD buffer backup power, a deliberate cold start, or MD initialization request via MD 11200. This is an informational alarm that documents a system state change rather than a fault condition.
Safety
Causes and Fixes
Check backup battery status on the NCK board. Verify battery voltage (typically 3.6V lithium cell) using a multimeter on connector pins designated for backup power. Battery life is typically 5-10 years.
Do not attempt battery replacement without proper ESD precautions and documented procedure per Siemens service manual.
Verify UPS/PSU output voltage stability. Check 24VDC and 5VDC supply rails on the control cabinet using oscilloscope. Look for voltage sag events that trigger POWER_FAIL input (typically active low when supply < 18VDC).
Monitor alarm log via HMI or Siemens SCOUT software. Cross-reference 4060 occurrence timestamp with power event logs. If pattern shows repeated 4060 after brief power interruptions, the backup battery or PSU regulation requires replacement.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.