Siemens 301705 - Axis drive distance-coded scale incorrectly parameterized
This alarm occurs when a distance-coded scale is selected (MD 1011.7=1) without configuring a length measuring system (MD 1011.4=1) or when MDs 1040, 1041, and 1042 are zero or negative. Fix by correctly parameterizing the machine data.
Siemens 301705 - Axis drive distance-coded scale incorrectly parameterized
Axis drive distance-coded scale incorrectly parameterized
When selecting a distance-coded scale (MD 1011.7=1) it is also necessary to configure a length measuring system (MD 1011.4=1). In addition, the MDs 1040, 1041 and 1042 must not be zero or negative Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
This alarm occurs when a distance-coded scale is selected (MD 1011.7=1) without configuring a length measuring system (MD 1011.4=1) or when MDs 1040, 1041, and 1042 are zero or negative. Fix by correctly parameterizing the machine data.
Safety
Causes and Fixes
Check MD 1011 settings
Verify that MD 1011.7=1 (distance-coded scale) and MD 1011.4=1 (length measuring system) are both set correctly.
Validate MD 1040-1042
Ensure MD 1040, 1041, and 1042 are not zero or negative; set appropriate positive values as per machine documentation.
Reset and test
Save changes, reset the control, and test the program to confirm the alarm is cleared.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.