Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

301708

Siemens 301708 - Axis drive actual value synchronisation not allowed

Axis drive actual value synchronisation not allowed

The actual value synchronization for drift/slippage in MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable) is deselected. This is only allowed with SBH/SG monitoring, since the absolute actual position is irrelevant for this type of monitoring. However, safe end position and/or cam monitoring is also selected Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The actual value synchronization for drift/slippage in MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable) is deselected.
  • This is only allowed with SBH/SG monitoring, since the absolute actual position is irrelevant for this type of monitoring.
  • However, safe end position and/or cam monitoring is also selected

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Deselect actual value synchronization for drift/slippage or the safe end position and/or safe cam monitoring in MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable).
  3. 3Switch control OFF - ON

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.