Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

301703

Siemens 301703 - Axis drive encoder/motor type are not compatible

Axis drive encoder/motor type are not compatible

If a linear motor was selected (motor selection menu), but no linear scale was configured (MD 1011.4=0), or if a rotary motor was selected, but a linear scale configured (MD 1011.4=1), then this error is triggered. Modify MD 1011: $MD_ACTUAL_VALUE_CONFIG (actual value sensing configuration IM) Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • If a linear motor was selected (motor selection menu), but no linear scale was configured (MD 1011.4=0), or if a rotary motor was selected, but a linear scale configured (MD 1011.4=1), then this error is triggered.
  • Modify MD 1011: $MD_ACTUAL_VALUE_CONFIG (actual value sensing configuration IM)

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Encoder type must be parameterized according to the motor type.
  3. 3Switch control OFF - ON

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.