Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300766

Siemens 300766 - Axis drive blocking frequency > Shannon frequency

Axis drive blocking frequency > Shannon frequency

The blocking frequency of a speed setpoint filter is greater than the Shannon sampling frequency from the sampling theorem Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The blocking frequency of a speed setpoint filter is greater than the Shannon sampling frequency from the sampling theorem

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Current setpoint filter: The value in MD 1210, 1213,1216 or 1219 must be smaller than the inverse value of two current controller cycles MD 1000: $MD_CURRENTCTRL_CYCLE_TIME (current controller cycle) (1/2*MD 1000 *31.25 microsec).
  3. 3Speciality with SINUMERIK 810D: Current setpoint filters 2,3 and 4 are calculated in the speed controller cycle.
  4. 4This means that MD 1213, 1216 or 1219 must be smaller than the inverse value of two speed controller cycles MD 1001: $MD_SPEEDCTRL_CYCLE_TIME (speed controller cycle) (1/2*MD 1001 *31.25 microsec).
  5. 5Clear alarm with the RESET key in all channels. Restart part program. 2-747