Siemens 300771 - Axis drive asynchronous mode: converter frequency invalid
Only a converter frequency of 4 kHz or 8 kHz is permitted in asynchronous mode (selected by MD 1465 < MD 1146). - Modify MD 1465: $MD_SWITCH_SPEED_MSD_AM (switchover speed MSD/AM) - Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed) The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Siemens 300771 - Axis drive asynchronous mode: converter frequency invalid
Axis drive asynchronous mode: converter frequency invalid
Only a converter frequency of 4 kHz or 8 kHz is permitted in asynchronous mode (selected by MD 1465 < MD 1146). - Modify MD 1465: $MD_SWITCH_SPEED_MSD_AM (switchover speed MSD/AM) - Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed) The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.