Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 300774 - Axis drive asynchronous mode: changeover speed invalid
This alarm occurs due to an invalid changeover speed setting in mixed MSD/AM operation, requiring modification of machine data (MD 1465 or MD 1466) to ensure closed-loop control in AM mode.
Siemens 300774 - Axis drive asynchronous mode: changeover speed invalid
Axis drive asynchronous mode: changeover speed invalid
In mixed operation MSD/AM (MD 1465 > 0) only closed-loop controlled AM mode is allowed (MD1466 <= MD1465). - Modify MD 1465: $MD_SWITCH_SPEED_MSD_AM (switchover speed MSD/AM) - Modify MD 1466: $MD_SWITCH_SPD_OPEN_LOOP_AM (switchover speed closed-loop/openloop control AM) The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Root Cause Summary
This alarm occurs due to an invalid changeover speed setting in mixed MSD/AM operation, requiring modification of machine data (MD 1465 or MD 1466) to ensure closed-loop control in AM mode.
Safety
Causes and Fixes
Check Machine Data
Access MD 1465 ($MD_SWITCH_SPEED_MSD_AM) and MD 1466 ($MD_SWITCH_SPD_OPEN_LOOP_AM) via the control panel.
Adjust Values
Ensure MD 1466 <= MD 1465 to enforce closed-loop control in AM mode as per alarm description.
Reset and Test
Save changes, reset the control, and test the program to confirm the alarm is cleared.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.