Siemens 840D 300780 - Axis drive zero load current > rated motor current
This alarm occurs when the no-load current (MD 1136) is set higher than the rated motor current (MD 1103), indicating a configuration error. Correct the machine data settings to resolve it.
Siemens 840D 300780 - Axis drive zero load current > rated motor current
Axis drive zero load current > rated motor current
Siemens SINAMICS drive alarm 300780: Axis drive zero load current > rated motor current. This alarm indicates a fault condition in the SINAMICS servo drive system. Refer to the Siemens SINAMICS fault list documentation for the complete remedy.
Root Cause Summary
This alarm occurs when the no-load current (MD 1136) is set higher than the rated motor current (MD 1103), indicating a configuration error. Correct the machine data settings to resolve it.
Safety
Causes and Fixes
Access Machine Data
Navigate to the machine data parameters in the Siemens control system.
Check Values
Compare MD 1136 (no-load current) with MD 1103 (rated motor current). Ensure MD 1136 is less than or equal to MD 1103.
Adjust and Save
Correct the value of MD 1136 if necessary, save changes, and reset the control.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?