Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300772

Siemens 300772 - Axis drive asynchronous mode: speed control gain too high

Axis drive asynchronous mode: speed control gain too high

The value in MD 1451: $MD_SPEEDCTRL_GAIN_1_AM (proportional gain of AM speed controller) is too high. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The value in MD 1451: $MD_SPEEDCTRL_GAIN_1_AM (proportional gain of AM speed controller) is too high.
  • The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready)

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2The current set in MD1451: $MD_SPEEDCTRL_GAIN_1_AM (proportional gain of AM speed controller).
  3. 3Clear alarm with the RESET key in all channels. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.