Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 300769 - Axis drive denominator bandwidth > double natural frequency
This alarm occurs when the bandwidth denominator of a current or speed setpoint filter exceeds twice the natural frequency due to incorrect machine data settings. Adjust the relevant MD parameters to resolve.
Siemens 300769 - Axis drive denominator bandwidth > double natural frequency
Axis drive denominator bandwidth > double natural frequency
The bandwidth denominator of a current or speed setpoint filter is greater than twice the natural frequency. This error message is only issued for the general bandstop filter if: - Speed setpoint filter 1: - MD 1516 > 0.0 or - MD 1520 <> 100.0 - Speed setpoint filter 2: - MD 1519 > 0.0 or - MD 1521 <> 100.0 - Current setpoint filter 1: - MD 1212 > 0.0 - Current setpoint filter 2: - MD 1215 > 0.0 - Current setpoint filter 3: - MD 1218 > 0.0 - Current setpoint filter 4: - MD 1221 > 0.0 The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Root Cause Summary
This alarm occurs when the bandwidth denominator of a current or speed setpoint filter exceeds twice the natural frequency due to incorrect machine data settings. Adjust the relevant MD parameters to resolve.
Safety
Causes and Fixes
Check MD Parameters
Review MD 1516, 1519, 1520, and 1521 for the affected axis and drive.
Adjust Values
Ensure bandwidth denominator values are less than twice the natural frequency. Adjust as needed.
Reset and Test
Clear the alarm, reset the control, and test the program or axis movement.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.