Siemens 840D 2900 - Reboot is delayed

Reboot is delayed

Siemens SINUMERIK alarm 2900: Reboot is delayed. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.

Root Cause Summary

Alarm 2900 is a non-critical informational alarm that fires when the MMC (Man Machine Control Panel) initiates a system reboot via the PI (Programmable Interface) service '_N_IBN_SS' and MD 11410 $MN_REBOOT_DELAY_TIME is configured with a value greater than zero, causing the reboot sequence to be intentionally delayed. This alarm indicates the system is waiting during the configured delay period before executing the actual reboot.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Siemens HMI or engineering environment (SINUMERIK Operate or StartDrive) and navigate to Machine Data (MD) editor in NCK menu

  2. 2

    Locate MD 11410 $MN_REBOOT_DELAY_TIME and verify the current value in milliseconds

  3. 3

    If delay is not required for your process, set MD 11410 $MN_REBOOT_DELAY_TIME to 0 to eliminate alarm 2900 on future reboots

    Setting to 0 removes safety delay for graceful PLC/NCK shutdown coordination; verify this is acceptable with your automation design

  4. 4

    Save MD changes and trigger a system reboot via MMC/PI '_N_IBN_SS' command to confirm alarm 2900 no longer appears

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.