Siemens 27002 - Axis test stop is running
SIEMENS alarm 27002 occurs when the NC kernel blocks the interpreter from reading ahead in the program due to unmet safety or operational prerequisites. This typically results from PLC interlocks, channel state conflicts, or protective responses to other active system faults that prevent safe program execution.
Siemens 27002 - Axis test stop is running
Axis test stop is running
Proper functioning of the switch-off path is just being tested by setting of the SGE "Test stop selection" Control reaction: Alarm display.
Root Cause Summary
SIEMENS alarm 27002 occurs when the NC kernel blocks the interpreter from reading ahead in the program due to unmet safety or operational prerequisites. This typically results from PLC interlocks, channel state conflicts, or protective responses to other active system faults that prevent safe program execution.
Safety
Causes and Fixes
Check PLC Interface Status
Navigate to Diagnostics > PLC > Interface Signals and examine DB31.DBX status bits for active interlocks.
Look specifically at DB31.DBX1.0 (Emergency Stop) and DB31.DBX1.1 (Feed Enable) status
Verify Safety Door Status
Check machine data MD11210 $MN_SAFE_DOOR_MASK and corresponding PLC inputs for door/guard positions.
Never bypass safety interlocks - resolve the underlying safety condition
Review PLC Program Logic
Use STEP 7 or TIA Portal to examine PLC program blocks FB1-FB3 for interlock conditions and reset requirements.
Check for latched fault conditions that require manual reset even after the physical condition is cleared
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.