Siemens 26100 - Axis drive sign of life missing

Axis drive sign of life missing

Special case: The output of drive number=0 indicates that a computing timeout occurred on the IPO level (see also alarm 4240) Control reaction: NC not ready. The NC switches to follow-up mode. Mode group not ready, also effective for single axes. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Root Cause Summary

SIEMENS alarm 26100 'Drive: SMI Error' indicates a malfunction in the Serial Measurement Interface (SMI) communication between the drive and encoder system. This typically results from encoder communication failures, cable issues, or drive module hardware problems affecting position feedback accuracy.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Causes and Fixes

  1. 1

    Check SMI Encoder Status

    Navigate to HMI > Diagnostics > Drive > Encoder and verify SMI encoder communication status. Check parameter P0404 (encoder type) shows correct SMI encoder configuration.

    Parameter P0491.0 shows the actual encoder communication status - should read 'OK' for proper SMI function.

  2. 2

    Verify Encoder Power Supply

    Measure encoder supply voltage at X521 terminals. SMI encoders typically require 5V ±5%. Check parameter P0595 for encoder supply monitoring status.

    Ensure drive is in safe state before accessing terminal connections.

  3. 3

    Test SMI Signal Quality

    Use STARTER software to access drive diagnostics and check SMI signal quality indicators. Monitor parameters P0493 (encoder error counter) and P0494 (encoder warning counter).

    Incrementing error counters indicate intermittent communication issues even if encoder appears functional.

DIY Feasiblemedium confidence

Call a technician if:

  • ·SMI interface hardware fault confirmed
  • ·Multiple encoder failures on same drive
  • ·Persistent alarms after cable and parameter verification

Prevention

  • Use only Siemens-approved SMI encoder cables
  • Maintain proper cable routing away from power circuits
  • Regular SMI signal quality monitoring via P0493/P0494
  • Keep encoder connections clean and properly sealed

Common Mistakes

  • Using standard encoder cables for SMI applications
  • Grounding SMI cable shield at both ends
  • Ignoring incremental encoder error counters
  • Mixing SMI and standard incremental encoder parameters

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.