Siemens SINUMERIK Controller
System · Basic · 15-30 minutes
Siemens 26000 - Axis clamping monitoring
SIEMENS alarm 26000 is triggered when the NCK receives a fault signal from one or more SINAMICS drive objects, indicating an out-of-tolerance condition detected by the drive's internal protection circuits. The specific fault code must be read from r0945 in the SINAMICS drive diagnostic buffer to identify the exact cause.
Siemens 26000 - Axis clamping monitoring
Axis clamping monitoring
The clamped axis has been pushed out of its setpoint position. The permissible difference is defined in the axis-specific MD36050 $MA_CLAMP_POS_TOL. Clamping an axis is activated with the axis-specific interface signal DB31,. DBX2.3 (Clamping process active). The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: Mode group not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Root Cause Summary
SIEMENS alarm 26000 is triggered when the NCK receives a fault signal from one or more SINAMICS drive objects, indicating an out-of-tolerance condition detected by the drive's internal protection circuits. The specific fault code must be read from r0945 in the SINAMICS drive diagnostic buffer to identify the exact cause.
Safety
Causes and Fixes
Check SINAMICS diagnostic buffer
Navigate to HMI → Diagnostics → Drive → select affected axis → read r0945[0-7] fault buffer to identify specific overtemperature fault code (typically F30001-F30008 range).
r0945[0] shows the most recent fault, check all buffer entries for pattern analysis
Verify cooling system operation
Check cabinet fans, motor cooling fan operation, and verify r0035 (inverter temperature) and r0037 (motor temperature) values in SINAMICS Startdrive or HMI drive monitoring.
Allow 30+ minutes cooldown before restart attempts
Inspect motor and cable routing
Check for blocked motor cooling passages, verify motor cable routing away from heat sources, and confirm p0625 (motor overtemperature threshold) parameter setting matches motor specifications.
Clear fault and monitor
After cooling, clear drive faults via HMI → Diagnostics → Drive → Reset or use SINAMICS p0952=1, then monitor temperature values during operation.
Set up r0035/r0037 monitoring in HMI trace to track temperature trends
Call a technician if:
Prevention
Common Mistakes