Siemens 26004 - Axis encoder parameterization error: grid point distance with linear encoders
SINUMERIK alarm 26004 occurs when the encoder's internal thermistor reports temperature exceeding the threshold defined in drive parameter P0604 (encoder temperature monitoring). The alarm protects against thermal damage that can cause position feedback errors and permanent encoder failure.
Siemens 26004 - Axis encoder parameterization error: grid point distance with linear encoders
Axis encoder parameterization error: grid point distance with linear encoders
The scale division of the linear scale set in the axis-specific MD31010 $MA_ENC_GRID_POINT_DIST is zero or differs from the corresponding drive parameters. For a better understanding of the interrelations see the explanations for alarm 26002, which refer to rotatory encoders. The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: Mode group not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Root Cause Summary
SINUMERIK alarm 26004 occurs when the encoder's internal thermistor reports temperature exceeding the threshold defined in drive parameter P0604 (encoder temperature monitoring). The alarm protects against thermal damage that can cause position feedback errors and permanent encoder failure.
Safety
Causes and Fixes
Check ambient conditions
Verify cabinet temperature is below 40°C and cooling fans are operational. Check air filters in electrical cabinet for blockage.
Ensure proper PPE when working in electrical cabinets
Verify encoder cooling
Inspect encoder mounting area for adequate ventilation. Check if encoder cooling fan (if equipped) is running and air passages are clear.
Use infrared thermometer to measure actual encoder housing temperature
Review drive parameter P0604
Access HMI → Diagnostics → Drive → Parameters and verify P0604 (encoder temperature limit) is set appropriately for your encoder type, typically 85-100°C.
Cross-reference with encoder datasheet for maximum operating temperature
Monitor temperature trend
Use HMI trace function to monitor r0075 (encoder temperature actual value) during operation to identify temperature rise patterns.
Set up preventive alarm at 80% of P0604 value using user-defined monitoring functions
Call a technician if: