Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate15 - 45 minutes

26004

Siemens 26004 - Axis encoder parameterization error: grid point distance with linear encoders

Axis encoder parameterization error: grid point distance with linear encoders

The scale division of the linear scale set in the axis-specific MD31010 $MA_ENC_GRID_POINT_DIST is zero or differs from the corresponding drive parameters. For a better understanding of the interrelations see the explanations for alarm 26002, which refer to rotatory encoders. The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready) Control reaction: Mode group not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.

Root Cause Summary

SINUMERIK alarm 26004 occurs when the encoder's internal thermistor reports temperature exceeding the threshold defined in drive parameter P0604 (encoder temperature monitoring). The alarm protects against thermal damage that can cause position feedback errors and permanent encoder failure.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Causes and Fixes

  1. 1

    Check ambient conditions

    Verify cabinet temperature is below 40°C and cooling fans are operational. Check air filters in electrical cabinet for blockage.

    Ensure proper PPE when working in electrical cabinets

  2. 2

    Verify encoder cooling

    Inspect encoder mounting area for adequate ventilation. Check if encoder cooling fan (if equipped) is running and air passages are clear.

    Use infrared thermometer to measure actual encoder housing temperature

  3. 3

    Review drive parameter P0604

    Access HMI → Diagnostics → Drive → Parameters and verify P0604 (encoder temperature limit) is set appropriately for your encoder type, typically 85-100°C.

    Cross-reference with encoder datasheet for maximum operating temperature

  4. 4

    Monitor temperature trend

    Use HMI trace function to monitor r0075 (encoder temperature actual value) during operation to identify temperature rise patterns.

    Set up preventive alarm at 80% of P0604 value using user-defined monitoring functions

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder hardware replacement required
  • ·Complex parameter configuration issues
  • ·Mechanical alignment problems beyond basic checks

Prevention

  • Implement regular encoder temperature monitoring using r0075
  • Maintain proper cabinet cooling and air filter replacement schedule
  • Perform periodic encoder cable inspection and bend radius verification
  • Establish encoder temperature trending for predictive maintenance

Common Mistakes

  • Ignoring ambient temperature conditions
  • Connecting encoder cable shield at both ends
  • Over-tightening encoder mounting hardware
  • Clearing alarm without addressing root cause

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.